Jindal Composite Tubes Pvt. Ltd. is the ultimate destination to avail optimum quality
uPVC Well Casing Pipes. The protector range of PVC plain casing and ribbed screen pipes is specially designed to ensure clean and clear water from bore wells, whether shallow or deep. The entire assortment of uPVC Well Casing Pipes is manufactured as per IS 12818 and DIN 4925 Standards. The immunity of these uPVC Well Casing Pipes to galvanic or electrolytic erosion, self -extinguishing nature, surface corrosion resistance, opposition to bacterial growth and zero encrustation make these uPVC Well Casing Pipes high on demand by the clients.
Advantages
- Immune to galvanic or electrolytic erosion
- No Surface corrosion
- No protective coating required
- Not affected by acids, alkalis, oils Et fats
- Better fire resistance due to self -extinguishing nature of uPVC
- Very smooth inside and outside surfaces, so lower frictional losses
- Does not support bacterial growth
- No encrustation
- Trapezoidal threads make joints easy to handle and install
- No skilled labour required
- Continuous ribs on screen with horizontal slots, allow over double the entry
- Light-weight; hence easy to handle and transport
- Safe for potable water transportation
- Most economical in installation
- Reduces power consumption in the long run
- Maintenance-free
- No painting required
Applications
- Bore-well Casing, Irrigation, Domestic, Industrial mining, Chemical Distribution.
- A better alternative to MS, ERW, GI, Asbestos, Cement and SS Pipes
- uPVC is almost inert to corrosion and chemical reaction. Hence, it can be used in salty, sandy and
- chemically aggressive water, without creating problems letter on.
Range
Jindal Casing Pipes are available as follows :
- Up to 80 meters depth-Shallow well pipes (CS Pipes) and
- Up to 250 meters depth-Medium Well Pipes (CM Pipes)
These pipes are available in sizes from 100mm D.N. to 200mm D.N... In the lengths of 2,3 or 4 meters in blue colour. These pipes have male threads at one end and female threads at the other end, as per Din 2999/103 or BS 21.
Installation
- Since uPVC pipes are lighter, they are easy to handle, transport and install.
- A typical installation is shown alongside. For detailed instruction, refer our installation manual
Design
- Specification followed : IS 12818:1995.
- Surface finish of this pipe is extremely smooth, which reduces hydraulic friction.
- Internal and external threading and bell-spigot ends ensure easy and reliable joining.
- Ribbed screen pipes are used especially when the outer surface area of a bore-well casing pipe is to be increased. The ribs provide around 25% additional surface area by virtue of their design. Besides that, it holds gravel balls away from the pipe, at a distance of about 2mm. This arrangement cleans slits naturally due to vertical flow passage and allows more water to seep in, resulting in higher yield than other plain screen pipes with the same bore.
Material
A combination to formulate perfect uPVC is achieved with the right selection of resins, heat stabilizers, lubricants, processing aids, impact modifiers and essential additives. We ensure all the ingredients and process parameters taken in the correct proportion.
Dimension of 'CS' Casing Pipes - for well depth upto 80 meters
Nominal Diameter DN |
Mean Outside Dia of Pipe |
Outside Dia of Pipe at any Point |
Mean Outside Dia Over Connection |
Wall Thickness |
DN |
Min |
Max |
Min |
Max |
Max |
Min |
Max |
150 |
165 |
165.4 |
164.8 |
165.6 |
174 |
5.7 |
6.5 |
175 |
200 |
200.5 |
199.8 |
200.6 |
211 |
7 |
7.8 |
200 |
225 |
225.5 |
224.8 |
225.8 |
238 |
7.6 |
8.8 |
250 |
280 |
280.5 |
279.6 |
280.8 |
292 |
9.6 |
11 |
Note : In addition to the above range we also refer 125CS, 180CS & 225CS plain and any other casing pipe as per specific requirement.
Dimension of 'CM' Casing Pipes - for well depth between 80-250 meters
Nominal Diameter |
Mean Outside Dia of Pipe |
Outside Dia of Pipe at any Point |
Mean Outside Dia Over Connection |
Wall Thickness |
DN |
Min |
Max |
Min |
Max |
Max |
Min |
Max |
40 |
48 |
48.2 |
48 |
48.3 |
52 |
3.5 |
4 |
50 |
60 |
60.2 |
59.9 |
60.3 |
65 |
4 |
4.6 |
80 |
88 |
88.3 |
88 |
88.4 |
94 |
4 |
4.6 |
100 |
113 |
113.3 |
112.9 |
113.4 |
120 |
5 |
5.7 |
125 |
140 |
140.4 |
139.9 |
140.5 |
150 |
6.5 |
7.3 |
150 |
165 |
165.4 |
164.8 |
165.6 |
178 |
7.5 |
8.5 |
175 |
200 |
200.5 |
199.8 |
200.6 |
215 |
8.8 |
9.8 |
200 |
225 |
225.5 |
224.8 |
225.8 |
243 |
10 |
11.2 |
250 |
280 |
280.5 |
279.6 |
280.8 |
298 |
12.5 |
14 |
Note : In addition to the above range we also refer 180CM & 225CM plain and any other casing pipe as per specific requirement.
Dimension of Screen Pipe with RIBS
Nominal Diameter |
Mean Outside Dia of Pipe |
Outside Dia of Pipe at any Point |
Mean Outside Dia Over Connection |
Wall Thickness |
DN |
Min |
Max |
Max |
Min |
Max |
40 |
52 |
51.9 |
56 |
3.5 |
4 |
50 |
64 |
63.9 |
69 |
4 |
4.6 |
80 |
92 |
91.8 |
98 |
4 |
4.6 |
100 |
117 |
116.8 |
124 |
5 |
5.7 |
150 |
168 |
168.6 |
182 |
7.5 |
8.5 |
200 |
229 |
228.5 |
247 |
10 |
11.2 |
SDR 52 - for well depth upto 40 feet (12 meters)
Size Class |
Mean Outside Dia of Pipe |
Outside Dia of Pipe at any Point |
Wall Thickness |
Length Tolerance |
Min |
Max |
Min |
Max |
Min |
Max |
Plain(m) |
Socketed(m) |
110 SDR - 52 |
110 |
110.4 |
108.6 |
111.4 |
2.1 |
2.4 |
-- |
6.01 |
140 SDR - 52 |
140 |
140.5 |
138.3 |
141.7 |
2.7 |
3.2 |
-- |
6.01 |
160 SDR - 52 |
160 |
160.5 |
158 |
162 |
3.1 |
3.5 |
-- |
6.01 |
180 SDR - 52 |
180 |
180.6 |
177.8 |
182.2 |
3.5 |
3.9 |
-- |
6.01 |
200 SDR - 52 |
200 |
200.6 |
197.6 |
202.4 |
3.8 |
4.3 |
-- |
6.01 |
SDR 35 - for well depth upto 60-90 feet (18-24 meters)
Size Class |
Mean Outside Dia of Pipe |
Outside Dia of Pipe at any Point |
Wall Thickness |
Length Tolerance |
Min |
Max |
Min |
Max |
Min |
Max |
Plain(m) |
Socketed(m) |
110 SDR - 35 |
110 |
110.4 |
108.6 |
111.4 |
3.1 |
3.5 |
-- |
6.01 |
125 SDR - 35 |
125 |
125.4 |
123.5 |
126.5 |
3.6 |
4 |
-- |
6.01 |
140 SDR - 35 |
140 |
140.5 |
138.3 |
141.7 |
4 |
4.5 |
-- |
6.01 |
160 SDR - 35 |
160 |
160.5 |
158 |
162 |
4.5 |
4.9 |
-- |
6.01 |
180 SDR - 35 |
180 |
180.6 |
177.8 |
182.2 |
5.1 |
5.6 |
-- |
6.01 |
200 SDR - 35 |
200 |
200.6 |
197.6 |
202.4 |
5.7 |
6.3 |
-- |
6.01 |
225 SDR - 35 |
225 |
225.7 |
222.3 |
227.5 |
6.4 |
7 |
-- |
6.01 |